• maliciousonion@lemmy.mlOP
    link
    fedilink
    English
    arrow-up
    2
    ·
    1 month ago

    I used the GUI program for SMART and the list of issues got marked as “old age”, all of them.

    • Atemu@lemmy.ml
      link
      fedilink
      arrow-up
      1
      ·
      30 days ago

      They meant the SMART self-test, not SMART data readout. Those are not meant to be interpreted by laymen and often not even experts.

      • maliciousonion@lemmy.mlOP
        link
        fedilink
        English
        arrow-up
        1
        ·
        edit-2
        29 days ago

        I did perform the self-test function, the long version that says it will take 10s of minutes. Some of the errors were displayed with red text before the test. After the self test, it said that my drive passed and all the red errors showed up as “Old age” in black text, every single one.

        (This is in the GUI app for smartctl)

        • Atemu@lemmy.ml
          link
          fedilink
          arrow-up
          2
          ·
          edit-2
          29 days ago

          Please stop trying to interpret the SMART data report. Even if you’re knowledgeable it can easily mislead you because this is vendor-specific data that follows no standard and is frequently misinterpreted by even the program displaying the data.

          If the self-test passed, it’s likely the cable or the controller. Try a different cable.